Part Number Hot Search : 
TCH10A15 E100502 CY2546I 61581 FR154G 55N03 ALN1970 P4KE16A
Product Description
Full Text Search
 

To Download PF500A-360 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 PF-A-SERIES
PFHC module 500W, 1000W
Model name
PF 1000A-360
Name of series Nominal output power Nominal output voltage
Features
marking (Low Voltage Directive) PFHC module Conforms to IEC 1000-3-2 High power factor: 0.95, high efficiency: 90% Input: 85 ~ 265VAC Output: 500, 1000W Wide baseplate temperature: -20 ~ +85C Conduction cooling Provided in-rush current limiting N+1 parallel redundant operation 2 year warranty
(Low Voltage Directive)
2 year warranty
Power Module
Specifications
01. Input voltage range 85 ~ 265VAC (50/60Hz) PFHC range: 85 ~ 255VAC (50/60Hz) 02. Output PF500A-360/85 ~ 265VAC input: DC360V 1.4A 504W voltage/current PF500A-360/170 ~ 265VAC input: DC360V 2.1A 756W PF1000A-360/85 ~ 265VAC input: DC360V 2.8A 1008W PF1000A-360/170 ~ 265VAC input: DC360V 4.2A 1512W Output derating by input voltage/PF500A: 80% for 85VAC, 100% for 100 ~ 265VAC Output derating by input voltage/PF1000A: 85% for 85VAC, 100% for 95 ~ 265VAC 03. Efficiency (typ) 90% (100VAC, full load), 94% (200VAC, full load) 04. Power factor 0.95 (100VAC/200VAC at full load) 05. In-rush current In-rush current limiting circuit: External limit resistor 06. Parallel operation N+1 redundant operation. Output current balancing (PC terminal) 07. Cooling Conduction cooling (Heatsink & airflow has to be chosen according to instruction manual) 08. Operating ambient Baseplate temperature: -20 ~ +85C (output derating is different according to condition) temperature Ambient temperature: above -20C 09. Withstand voltage Input/output terminal to baseplate: 3.0kVAC for 1 min. 10. Safety standard Approved by UL1950 , CSA950(C-UL) , and EN60950 (BSI) 11. Functions Over voltage, Thermal protection, PFHC power on signal (ENA terminal), Inverter good signal (IOG terminal), Auxiliary power supply for external signal (AUX terminal) 12. Recommended PN-F series noise filter
Product lineup
Model Nominal voltage range 100 ~ 240VAC PF500A-360 200 ~ 240VAC 100 ~ 240VAC PF1000A-360 200 ~ 240VAC Input voltage range 85 ~ 265VAC (47 ~ 63Hz) 170 ~ 265VAC (47 ~ 63Hz) 85 ~ 265VAC (47 ~ 63Hz) 170 ~ 265VAC (47 ~ 63Hz)
Note 1
PFHC operation Nominal Input current (typ) input voltage range output voltage 85 ~ 255VAC (47 ~ 63Hz) 170 ~ 255VAC (47 ~ 63Hz) 85 ~ 225VAC (47 ~ 63Hz) 170 ~ 255VAC (47 ~ 63Hz) 5.6A 4.0A 11.2A 8.0A 360VDC 360VDC 360VDC 360VDC
Max. output current 1.4A 2.1A 2.8A 4.2A
Max. output power 504W 756W 1008W 1512W
UL
CSA
EN
Request customer specification for further details of specifications, outline, characteristics, etc. Read the instruction manual before usage. Contact us about delivery before ordering.
: Safety standard approved
Block diagram
Note 1: Standard for input 100/200VAC and max. output power. Note 1: The above specified value is on condition with external components attached. Filtering capacitor and in-rush current limiting resistor are required as external components. Attach an external fuse at input line.
101
PF-A-SERIES
PF500A-360
Power Module
Note 1: "Model name, Input voltage range, Nominal output voltage, Maximum output current and country of manufacture are shown here. Note 2: Input & output terminal 5-o2 5-o0.6
(Unit: mm)
PF1000A-360
Note 1: "Model name, Input voltage range, Nominal output voltage, Maximum output current and country of manufacture are shown here. Note 2: Input & output terminal 5-o2 5-o0.6
(Unit: mm)
102


▲Up To Search▲   

 
Price & Availability of PF500A-360

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X